Fangyu(shanghai)Automation Technology Co.,Ltd

Fangyu(shanghai)Automation Technology Co.,Ltd

Manufacturer from China
Verified Supplier
2 Years
Home / Products / High Voltage Power Cables /

High Voltage Power Cables Cu/XLPE/CAS/PVC XLPE Insulated Underground Power Cable

Contact Now
Fangyu(shanghai)Automation Technology Co.,Ltd
Visit Website
City:shanghai
Province/State:shanghai
Country/Region:china
Contact Person:MrsNora
Contact Now

High Voltage Power Cables Cu/XLPE/CAS/PVC XLPE Insulated Underground Power Cable

Ask Latest Price
Video Channel
Certification :ISO, CCC, CE, RoHS, TUV
Model NO. :YJLW02
Wire Core Material :Bare Copper Wire
Model :Yjlw02
Brand :Qifan
Standard :IEC 60840 IEC 62067
No. of Core :Single Core
Transport Package :Drum
Specification :240-2500mm2
Trademark :QIFAN
Origin :China
HS Code :8544601300
Supply Ability :50000K Meter/ per Month
Application :Construction, Underground, Industrial, Power Station
Voltage :High Voltage Cable
Current :DC & AC
Insulation Material :XLPE
Sheath Material :PVC
Material Shape :Round Wire
Samples :US$ 0/Meter 1 Meter(Min.Order) | Request Sample
Place of Origin :China
Brand Name :Qifan
MOQ :100m
Price :usd3-8/meter
Packaging Details :wooden drumsPackaging Details Inner Packing: Wooden reel, Plastic reel, and Paper Reel Outer Packing: Carton box, Pull out box, Pallet available Other packing available according to clients' request
Delivery Time :30-45days
Payment Terms :D/A, D/P, L/C, T/T, Western Union, MoneyGram
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Product Description

CU/XLPE/CAS/PVC 66kV 110kV 220kV XLPE Insulated Underground Power Cable

Voltage grade is up to 220kv, cross-section area can be up to 2500 sqmm (copper or aluminiun conductor). Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more than 250 degrees.

2. Brief Construction:
Single core
Copper or aluminium conductor
XLPE insulation

Corugation aluminum sheath
PVC or PE sheath

3. Laying conditions: For lyaing under ground with large different altitude, be able to bear external machanical force and moderate pulling force

4. MANUFACTURING FEATURES
Conductor

The conductor shall be round compact stranded copper or aluminum wires. The resistance of each conductor at 20ºC shall be in accordance with IEC 60228 standard. The surface of the conductor shall be clean and free from any foreign particles, which may contaminate the insulation or cause high electrical field stress in the conductor screen.
Conductor screen, Insulation and Insulation screen
Extrusion of conductor screen, insulation and insulation screen shall be by single pass, triple extrusion method. Conductor screen, XLPE main insulation and insulation screen shall be produced by triple extrusion and dry curing.
Conductor screen shall consist of semi-conducting tapes applied over the conductor and a continuous layer of extruded semiconducting XLPE compound covering the entire surface area of the conductor and firmly bonded to the inner surface of the insulation.
The insulation shall be XLPE and shall be applied by extrusion and cross-linked to form a compact and homogeneous layer in accordance with the Standards specified. The insulation material shall be of Super Clean polyethylene mixture suitable for cross-linking (XLPE).
Insulation screen shall consist of a layer of extruded non-strippable semi-conducting thermosetting compound.

After triple extrusion, the insulated cores shall be degassed to remove the by-product in the core from the cross-linking process.

Bedding
Semi-conducting water-blocking tapes (swellable tapes) over the insulation screen shall be applied to prevent longitudinal water penetration between insulation screening and metallic sheath. The swellable tape shall cover the entire surface area of the insulation screen.

Metallic sheath
Corrugation Aluminum sheath shall be applied over the semi-conducting water blocking tape to accommodate the required radical water tightness and protect the insulation core.

Outer sheath
The outer-sheath shall be of an extruded layer of black color PVC.It shall be highly chemical resistance and withstand the mechanical force during fabrication, transit,installation and operation.
Outer conductive layer
A coating of Graphite shall be applied over the over sheath to carry out D.C. Voltage Test.


1. The products are mainly complying with IEC 60840 IEC 62067 standard, also can be produced according to OEM requirements and other standards, such as bs standard, DIN standard, ASTM standard, etc.
High Voltage Power Cables Cu/XLPE/CAS/PVC XLPE Insulated Underground Power CableHigh Voltage Power Cables Cu/XLPE/CAS/PVC XLPE Insulated Underground Power CableHigh Voltage Power Cables Cu/XLPE/CAS/PVC XLPE Insulated Underground Power CableHigh Voltage Power Cables Cu/XLPE/CAS/PVC XLPE Insulated Underground Power CableHigh Voltage Power Cables Cu/XLPE/CAS/PVC XLPE Insulated Underground Power CableHigh Voltage Power Cables Cu/XLPE/CAS/PVC XLPE Insulated Underground Power Cable

Shanghai Qifan Cable Test Centre was Approved by CNAS

2022-07-18

On February 21, 2019, Shanghai Qifan Cable Test Center was approved by cnas and obtained the certificate.

Inquiry Cart 0